| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A remote code execution vulnerability exists in HybridAuth versions 2.0.9 through 2.2.2 due to insecure use of the install.php installation script. The script remains accessible after deployment and fails to sanitize input before writing to the application’s config.php file. An unauthenticated attacker can inject arbitrary PHP code into config.php, which is later executed when the file is loaded. This allows attackers to achieve remote code execution on the server. Exploitation of this issue will overwrite the existing configuration, rendering the application non-functional. |
| A command injection vulnerability exists in the eScan Web Management Console version 5.5-2. The application fails to properly sanitize the 'pass' parameter when processing login requests to login.php, allowing an authenticated attacker with a valid username to inject arbitrary commands via a specially crafted password value. Successful exploitation results in remote code execution. Privilege escalation to root is possible by abusing the runasroot utility with mwconf-level privileges. |
| An unauthenticated remote command execution vulnerability exists in Pandora FMS versions up to and including 5.0RC1 via the Anyterm web interface, which listens on TCP port 8023. The anyterm-module endpoint accepts unsanitized user input via the p parameter and directly injects it into a shell command, allowing arbitrary command execution as the pandora user. In certain versions (notably 4.1 and 5.0RC1), the pandora user can elevate privileges to root without a password using a chain involving the artica user account. This account is typically installed without a password and is configured to run sudo without authentication. Therefore, full system compromise is possible without any credentials. |
| FLIR Thermal Camera F/FC/PT/D Stream firmware version 8.0.0.64 contains an unauthenticated vulnerability that allows remote attackers to access live camera streams without credentials. Attackers can exploit the vulnerability to view unauthorized thermal camera video feeds across multiple camera series without requiring any authentication. |
| An unauthenticated remote attacker can get access without password protection to the affected device. This enables the unprotected read-only access to the stored measurement data. |
| The SAP Internet Communication Framework does not conduct any authentication checks for features that need user identification allowing an attacker to reuse authorization tokens, violating secure authentication practices causing low impact on Confidentiality, Integrity and Availability of the application. |
| By default, the Packet Power Monitoring and Control Web Interface do not
enforce authentication mechanisms. This vulnerability could allow
unauthorized users to access and manipulate monitoring and control
functions. |
| The wifi module exposes the interface and has improper permission control, leaking sensitive information about the device. |
| Locally installed application can bypass the permission check and perform system operations that require permission. |
| An attacker could modify or disable settings, disrupt fuel monitoring
and supply chain operations, leading to disabling of ATG monitoring.
This would result in potential safety hazards in fuel storage and
transportation. |
| An unauthenticated remote attacker who is aware of a MQTT topic name can send and receive messages, including GET/SET configuration commands, reboot commands and firmware updates. |
| A vulnerability has been identified in which Rancher does not automatically clean up a user which has been deleted from the configured authentication provider (AP). This characteristic also applies to disabled or revoked users, Rancher will not reflect these modifications which may leave the user’s tokens still usable. |
| A Missing Authentication for Critical Function issue affecting the HTTP service running on the DJI Mavic Mini 3 Pro on the standard port 80 could allow an attacker to enumerate and download videos and pictures saved on the drone internal or external memory without requiring any kind of authentication. |
| wandb/openui latest commit c945bb859979659add5f490a874140ad17c56a5d contains a vulnerability where unauthenticated endpoints allow file uploads and downloads from an AWS S3 bucket. This can lead to multiple security issues including denial of service, stored XSS, and information disclosure. The affected endpoints are '/v1/share/{id:str}' for uploading and '/v1/share/{id:str}' for downloading JSON files. The lack of authentication allows any user to upload and overwrite files, potentially causing the S3 bucket to run out of space, injecting malicious scripts, and accessing sensitive information. |
| Unauthenticated CROWN APIs allow access to critical functions. This leads to the accessibility of large parts of the web application without authentication. |
| Lua apps can be deployed, removed, started, reloaded or stopped without authorization via
AppManager. This allows an attacker to remove legitimate apps creating a DoS attack, read and write
files or load apps that use all features of the product available to a customer. |
| Certain modes of routers from Billion Electric have a Missing Authentication vulnerability, allowing unauthenticated remote attackers to directly access the specific functionality to obtain partial device information, modify the WiFi SSID, and restart the device. |
| SSL-VPN MFA Bypass in SonicWALL SSL-VPN can arise in specific cases due to the separate handling of UPN (User Principal Name) and SAM (Security Account Manager) account names when integrated with Microsoft Active Directory, allowing MFA to be configured independently for each login method and potentially enabling attackers to bypass MFA by exploiting the alternative account name. |
| The passwordless login mechanism in CGFIDO from Changing Information Technology has an Authentication Bypass vulnerability, allowing remote attackers with regular privileges to send a crafted request to switch to the identity of any user, including administrators. |
| The devices allow access to an unprotected endpoint that allows MPFS
file system binary image upload without authentication. The MPFS2 file
system module provides a light-weight read-only file system that can be
stored in external EEPROM, external serial flash, or internal flash
program memory. This file system serves as the basis for the HTTP2 web
server module, but is also used by the SNMP module and is available to
other applications that require basic read-only storage capabilities.
This can be exploited to overwrite the flash program memory that holds
the web server's main interfaces and execute arbitrary code. |