Export limit exceeded: 420867 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (4824 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2025-41718 | 1 Murrelektronik | 4 Firmware Impact67 Pro 54620, Firmware Impact67 Pro 54630, Firmware Impact67 Pro 54631 and 1 more | 2026-04-15 | 7.5 High |
| A cleartext transmission of sensitive information vulnerability in the affected products allows an unauthorized remote attacker to gain login credentials and access the Web-UI. | ||||
| CVE-2024-31486 | 2026-04-15 | 5.3 Medium | ||
| A vulnerability has been identified in OPUPI0 AMQP/MQTT (All versions < V5.30). The affected devices stores MQTT client passwords without sufficient protection on the devices. An attacker with remote shell access or physical access could retrieve the credentials leading to confidentiality loss. | ||||
| CVE-2025-8863 | 1 Yugabyte | 1 Yugabytedb | 2026-04-15 | 3.7 Low |
| YugabyteDB diagnostic information was transmitted over HTTP, which could expose sensitive data during transmission | ||||
| CVE-2025-4394 | 2026-04-15 | 6.8 Medium | ||
| Medtronic MyCareLink Patient Monitor uses an unencrypted filesystem on internal storage, which allows an attacker with physical access to read and modify files. This issue affects MyCareLink Patient Monitor models 24950 and 24952: before June 25, 2025 | ||||
| CVE-2025-26654 | 2026-04-15 | 6.8 Medium | ||
| SAP Commerce Cloud (Public Cloud) does not allow to disable unencrypted HTTP (port 80) entirely, but instead allows a redirect from port 80 to 443 (HTTPS). As a result, Commerce normally communicates securely over HTTPS. However, the confidentiality and integrity of data sent on the first request before the redirect may be impacted if the client is configured to use HTTP and sends confidential data on the first request before the redirect. | ||||
| CVE-2025-9513 | 1 Editso | 1 Fuso | 2026-04-15 | 3.7 Low |
| A flaw has been found in editso fuso up to 1.0.4-beta.7. This affects the function PenetrateRsaAndAesHandshake of the file src/net/penetrate/handshake/mod.rs. This manipulation of the argument priv_key causes inadequate encryption strength. Remote exploitation of the attack is possible. A high degree of complexity is needed for the attack. The exploitability is reported as difficult. | ||||
| CVE-2024-45718 | 2026-04-15 | 4.6 Medium | ||
| Sensitive data could be exposed to non- privileged users in a configuration file. Local access to the computer with a low- privileged account is required to access the configuration file containing the sensitive data. | ||||
| CVE-2025-7731 | 1 Mitsubishi Electric | 1 Melsec Iq-f Series | 2026-04-15 | 7.5 High |
| Cleartext Transmission of Sensitive Information vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series CPU module allows a remote unauthenticated attacker to obtain credential information by intercepting SLMP communication messages, and read or write the device values of the product and stop the operations of programs by using the obtained credential information. | ||||
| CVE-2024-46383 | 2026-04-15 | 2.4 Low | ||
| Hathway Skyworth Router CM5100-511 v4.1.1.24 was discovered to store sensitive information about USB and Wifi connected devices in plaintext. | ||||
| CVE-2025-59105 | 1 Dormakaba | 1 Access Manager | 2026-04-15 | N/A |
| With physical access to the device and enough time an attacker can desolder the flash memory, modify it and then reinstall it because of missing encryption. Thus, essential files, such as "/etc/passwd", as well as stored certificates, cryptographic keys, stored PINs and so on can be modified and read, in order to gain SSH root access on the Linux-based K7 model. On the Windows CE based K5 model, the password for the Access Manager can additionally be read in plain text from the stored SQLite database. | ||||
| CVE-2024-47789 | 1 D3dsecurity | 1 D8801 | 2026-04-15 | N/A |
| ** UNSUPPORTED WHEN ASSIGNED ** This vulnerability exists in D3D Security IP Camera D8801 due to usage of weak authentication scheme of the HTTP header protocol where authorization tag contain a Base-64 encoded username and password. A remote attacker could exploit this vulnerability by crafting a HTTP packet leading to exposure of user credentials of the targeted device. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. | ||||
| CVE-2024-53651 | 2026-04-15 | 4.6 Medium | ||
| A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions), SIPROTEC 5 6MD89 (CP300) (All versions), SIPROTEC 5 6MU85 (CP300) (All versions), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions), SIPROTEC 5 7SA82 (CP100) (All versions), SIPROTEC 5 7SA82 (CP150) (All versions), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions), SIPROTEC 5 7SD82 (CP100) (All versions), SIPROTEC 5 7SD82 (CP150) (All versions), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions), SIPROTEC 5 7SJ81 (CP100) (All versions), SIPROTEC 5 7SJ81 (CP150) (All versions), SIPROTEC 5 7SJ82 (CP100) (All versions), SIPROTEC 5 7SJ82 (CP150) (All versions), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions), SIPROTEC 5 7SK82 (CP100) (All versions), SIPROTEC 5 7SK82 (CP150) (All versions), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions), SIPROTEC 5 7SL82 (CP100) (All versions), SIPROTEC 5 7SL82 (CP150) (All versions), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions), SIPROTEC 5 7ST86 (CP300) (All versions), SIPROTEC 5 7SX82 (CP150) (All versions), SIPROTEC 5 7SX85 (CP300) (All versions), SIPROTEC 5 7SY82 (CP150) (All versions), SIPROTEC 5 7UM85 (CP300) (All versions), SIPROTEC 5 7UT82 (CP100) (All versions), SIPROTEC 5 7UT82 (CP150) (All versions), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions), SIPROTEC 5 7VE85 (CP300) (All versions), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions), SIPROTEC 5 7VU85 (CP300) (All versions), SIPROTEC 5 Compact 7SX800 (CP050) (All versions). Affected devices do not encrypt certain data within the on-board flash storage on their PCB. This could allow an attacker with physical access to read the entire filesystem of the device. | ||||
| CVE-2024-46505 | 2026-04-15 | 9.1 Critical | ||
| Infoblox BloxOne v2.4 was discovered to contain a business logic flaw due to thick client vulnerabilities. | ||||
| CVE-2025-5087 | 2026-04-15 | N/A | ||
| Kaleris NAVIS N4 ULC (Ultra Light Client) communicates insecurely using zlib-compressed data over HTTP. An attacker capable of observing network traffic between Ultra Light Clients and N4 servers can extract sensitive information, including plaintext credentials. | ||||
| CVE-2024-7396 | 1 Korenix | 1 Jetport 5601v3 | 2026-04-15 | N/A |
| Missing encryption of sensitive data in Korenix JetPort 5601v3 allows Eavesdropping.This issue affects JetPort 5601v3: through 1.2. | ||||
| CVE-2025-47698 | 1 Cognex | 1 In-sight Explorer | 2026-04-15 | N/A |
| An adjacent attacker without authentication can exploit this vulnerability to retrieve a set of user-privileged credentials. These credentials are present during the firmware upgrade procedure. | ||||
| CVE-2025-64389 | 1 Circutor | 1 Tcprs1plus | 2026-04-15 | N/A |
| The web server of the device performs exchanges of sensitive information in clear text through an insecure protocol. | ||||
| CVE-2024-36497 | 1 Faronics | 1 Winselect | 2026-04-15 | 9.1 Critical |
| The decrypted configuration file contains the password in cleartext which is used to configure WINSelect. It can be used to remove the existing restrictions and disable WINSelect entirely. | ||||
| CVE-2025-40753 | 1 Siemens | 2 Q100, Q200 | 2026-04-15 | 6.2 Medium |
| A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) (All versions >= V2.60 < V2.62), POWER METER SICAM Q200 family (All versions >= V2.70 < V2.80). Affected devices export the password for the SMTP account as plain text in the Configuration File. This could allow an authenticated local attacker to extract it and use the configured SMTP service for arbitrary purposes. | ||||
| CVE-2026-23662 | 1 Microsoft | 1 Azure Iot Explorer | 2026-04-14 | 7.5 High |
| Missing authentication for critical function in Azure IoT Explorer allows an unauthorized attacker to disclose information over a network. | ||||