Search Results (1930 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2017-14115 2 Att, Commscope 3 U-verse Firmware, Arris Nvg589, Arris Nvg599 2025-04-20 N/A
The AT&T U-verse 9.2.2h0d83 firmware for the Arris NVG589 and NVG599 devices, when IP Passthrough mode is not used, configures ssh-permanent-enable WAN SSH logins to the remotessh account with the 5SaP9I26 password, which allows remote attackers to access a "Terminal shell v1.0" service, and subsequently obtain unrestricted root privileges, by establishing an SSH session and then entering certain shell metacharacters and BusyBox commands.
CVE-2017-17107 1 Zivif 2 Pr115-204-p-rs, Pr115-204-p-rs Firmware 2025-04-20 N/A
Zivif PR115-204-P-RS V2.3.4.2103 web cameras contain a hard-coded cat1029 password for the root user. The SONIX operating system's setup renders this password unchangeable and it can be used to access the device via a TELNET session.
CVE-2017-15582 1 Writediary 1 Diary With Lock 2025-04-20 N/A
In net.MCrypt in the "Diary with lock" (aka WriteDiary) application 4.72 for Android, hardcoded SecretKey and iv variables are used for the AES parameters, which makes it easier for attackers to obtain the cleartext of stored diary entries.
CVE-2014-8426 1 Barracuda 1 Load Balancer 2025-04-20 N/A
Hard coded weak credentials in Barracuda Load Balancer 5.0.0.015.
CVE-2017-2343 1 Juniper 14 Junos, Srx100, Srx110 and 11 more 2025-04-20 N/A
The Integrated User Firewall (UserFW) feature was introduced in Junos OS version 12.1X47-D10 on the Juniper SRX Series devices to provide simple integration of user profiles on top of the existing firewall polices. As part of an internal security review of the UserFW services authentication API, hardcoded credentials were identified and removed which can impact both the SRX Series device, and potentially LDAP and Active Directory integrated points. An attacker may be able to completely compromise SRX Series devices, as well as Active Directory servers and services. When Active Directory is compromised, it may allow access to user credentials, workstations, servers performing other functions such as email, database, etc. Inter-Forest Active Directory deployments may also be at risk as the attacker may gain full administrative control over one or more Active Directories depending on the credentials supplied by the administrator of the AD domains and SRX devices performing integrated authentication of users, groups and devices. To identify if your device is potentially vulnerable to exploitation, check to see if the service is operating; from CLI review the following output: root@SRX-Firewall# run show services user-identification active-directory-access domain-controller status extensive A result of "Status: Connected" will indicate that the service is active on the device. To evaluate if user authentication is occurring through the device: root@SRX-Firewall# run show services user-identification active-directory-access active-directory-authentication-table all Next review the results to see if valid users and groups are returned. e.g. Domain: juniperlab.com Total entries: 3 Source IP Username groups state 172.16.26.1 administrator Valid 192.168.26.2 engg01 engineers Valid 192.168.26.3 guest01 guests Valid Domain: NULL Total entries: 8 Source IP Username groups state 192.168.26.4 Invalid 192.168.26.5 Invalid This will also indicate that Valid users and groups are authenticating through the device. Affected releases are Juniper Networks Junos OS 12.3X48 from 12.3X48-D30 and prior to 12.3X48-D35 on SRX series; 15.1X49 from 15.1X49-D40 and prior to 15.1X49-D50 on SRX series. Devices on any version of Junos OS 12.1X46, or 12.1X47 are unaffected by this issue.
CVE-2017-9956 1 Schneider-electric 1 U.motion Builder 2025-04-20 N/A
An authentication bypass vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which the system contains a hard-coded valid session. An attacker can use that session ID as part of the HTTP cookie of a web request, resulting in authentication bypass
CVE-2017-9932 1 Greenpacket 2 Dx-350, Dx-350 Firmware 2025-04-20 N/A
Green Packet DX-350 Firmware version v2.8.9.5-g1.4.8-atheeb has a default password of admin for the admin account.
CVE-2017-8224 1 Wificam 2 Wireless Ip Camera \(p2p\), Wireless Ip Camera \(p2p\) Firmware 2025-04-20 N/A
Wireless IP Camera (P2P) WIFICAM devices have a backdoor root account that can be accessed with TELNET.
CVE-2017-5230 1 Rapid7 1 Nexpose 2025-04-20 N/A
The Java keystore in all versions and editions of Rapid7 Nexpose prior to 6.4.50 is encrypted with a static password of 'r@p1d7k3y5t0r3' which is not modifiable by the user. The keystore provides storage for saved scan credentials in an otherwise secure location on disk.
CVE-2017-5167 1 Binom3 2 Universal Multifunctional Electric Power Quality Meter, Universal Multifunctional Electric Power Quality Meter Firmware 2025-04-20 N/A
An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Users do not have any option to change their own passwords.
CVE-2017-9852 1 Sma 78 Sunny Boy 1.5, Sunny Boy 1.5 Firmware, Sunny Boy 2.5 and 75 more 2025-04-20 N/A
An Incorrect Password Management issue was discovered in SMA Solar Technology products. Default passwords exist that are rarely changed. User passwords will almost always be default. Installer passwords are expected to be default or similar across installations installed by the same company (but are sometimes changed). Hidden user accounts have (at least in some cases, though more research is required to test this for all hidden user accounts) a fixed password for all devices; it can never be changed by a user. Other vulnerabilities exist that allow an attacker to get the passwords of these hidden user accounts. NOTE: the vendor reports that it has no influence on the allocation of passwords, and that global hardcoded master passwords do not exist. Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected
CVE-2017-2283 1 Iodata 2 Wn-g300r3, Wn-g300r3 Firmware 2025-04-20 N/A
WN-G300R3 firmware version 1.0.2 and earlier uses hardcoded credentials which may allow an attacker that can access the device to execute arbitrary code on the device.
CVE-2017-2280 1 Iodata 2 Wn-ax1167gr, Wn-ax1167gr Firmware 2025-04-20 N/A
WN-AX1167GR firmware version 3.00 and earlier uses hardcoded credentials which may allow an attacker that can access the device to execute arbitrary code on the device.
CVE-2017-2236 1 Toshiba 4 Hem-gw16a, Hem-gw16a Firmware, Hem-gw26a and 1 more 2025-04-20 N/A
Toshiba Home gateway HEM-GW16A firmware HEM-GW16A-FW-V1.2.0 and earlier, Toshiba Home gateway HEM-GW26A firmware HEM-GW26A-FW-V1.2.0 and earlier uses hard-coded credentials, which may allow attackers to perform operations on device with administrative privileges.
CVE-2017-9649 1 Mirion Technologies 14 Dmc 3000, Dmc 3000 Firmware, Drm-1\/2 and 11 more 2025-04-20 N/A
A Use of Hard-Coded Cryptographic Key issue was discovered in Mirion Technologies DMC 3000 Transmitter Module, iPam Transmitter f/DMC 2000, RDS-31 iTX and variants (including RSD31-AM Package), DRM-1/2 and variants (including Solar PWR Package), DRM and RDS Based Boundary Monitors, External Transmitters, Telepole II, and MESH Repeater (Telemetry Enabled Devices). An unchangeable, factory-set key is included in the 900 MHz transmitter firmware.
CVE-2017-15909 1 Dlink 2 Dgs-1500, Dgs-1500 Firmware 2025-04-20 N/A
D-Link DGS-1500 Ax devices before 2.51B021 have a hardcoded password, which allows remote attackers to obtain shell access.
CVE-2017-11743 1 Medhost 1 Connex 2025-04-20 N/A
MEDHOST Connex contains a hard-coded Mirth Connect admin credential that is used for customer Mirth Connect management access. An attacker with knowledge of the hard-coded credential and the ability to communicate directly with the Mirth Connect management console may be able to intercept sensitive patient information. The admin account password is hard-coded as $K8t1ng throughout the application, and is the same across all installations. Customers do not have the option to change the Mirth Connect admin account password. The Mirth Connect admin account is created during the Connex install. The plaintext account password is hard-coded multiple times in the Connex install and update scripts.
CVE-2017-11694 1 Medhost 1 Medhost Document Management System 2025-04-20 N/A
MEDHOST Document Management System contains hard-coded credentials that are used for Apache Solr access. An attacker with knowledge of the hard-coded credentials and the ability to communicate directly with Apache Solr may be able to obtain or modify sensitive patient and financial information. The Apache Solr account name is dms. The password is hard-coded throughout the application, and is the same across all installations. Customers do not have the option to change passwords. The dms account for Apache Solr has access to all indexed patient documents.
CVE-2017-11693 1 Medhost 1 Medhost Document Management System 2025-04-20 N/A
MEDHOST Document Management System contains hard-coded credentials that are used for customer database access. An attacker with knowledge of the hard-coded credentials and the ability to communicate directly with the database may be able to obtain or modify sensitive patient and financial information. PostgreSQL is used as the Document Management System database. The account name is dms. The password is hard-coded throughout the application, and is the same across all installations. Customers do not have the option to change passwords. The dms account for PostgreSQL has access to the database schema for Document Management System.
CVE-2017-11614 1 Medhost 1 Connex 2025-04-20 N/A
MEDHOST Connex contains hard-coded credentials that are used for customer database access. An attacker with knowledge of the hard-coded credentials and the ability to communicate directly with the database may be able to obtain or modify sensitive patient and financial information. Connex utilizes an IBM i DB2 user account for database access. The account name is HMSCXPDN. Its password is hard-coded in multiple places in the application. Customers do not have the option to change this password. The account has elevated DB2 roles, and can access all objects or database tables on the customer DB2 database. This account can access data through ODBC, FTP, and TELNET. Customers without Connex installed are still vulnerable because the MEDHOST setup program creates this account.