| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Ironic-image is an OpenStack Ironic deployment packaged and configured by Metal3. When the reverse proxy mode is enabled by the `IRONIC_REVERSE_PROXY_SETUP` variable set to `true`, 1) HTTP basic credentials are validated on the HTTPD side in a separate container, not in the Ironic service itself and 2) Ironic listens in host network on a private port 6388 on localhost by default. As a result, when the reverse proxy mode is used, any Pod or local Unix user on the control plane Node can access the Ironic API on the private port without authentication. A similar problem affects Ironic Inspector (`INSPECTOR_REVERSE_PROXY_SETUP` set to `true`), although the attack potential is smaller there. This issue affects operators deploying ironic-image in the reverse proxy mode, which is the recommended mode when TLS is used (also recommended), with the `IRONIC_PRIVATE_PORT` variable unset or set to a numeric value. In this case, an attacker with enough privileges to launch a pod on the control plane with host networking can access Ironic API and use it to modify bare-metal machine, e.g. provision them with a new image or change their BIOS settings. This vulnerability is fixed in 24.1.1. |
| The ClickCease Click Fraud Protection plugin for WordPress is vulnerable to unauthorized access of data due to an improper capability check on the get_settings function in all versions up to, and including, 3.2.4. This makes it possible for authenticated attackers, with author access and above, to retrieve the plugin's configured API keys. |
| A vulnerability was found in Tsinghua Unigroup Electronic Archives Management System 3.2.210802(62532). It has been classified as problematic. Affected is the function download of the file /Searchnew/Subject/download.html. The manipulation of the argument path leads to information disclosure. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. |
| An authentication bypass vulnerability could allow an attacker to access API functions without authentication. |
| Northern.tech Mender 3.3.x before 3.3.2 and 3.4.x before 3.4.0 has Incorrect Access Control and allows low-privileged users default read access to some sensitive device information. |
| An issue exists in SoftIron HyperCloud
where authenticated, but non-admin users can create data pools, which could potentially impact the performance and availability of the backend software-defined storage subsystem.
This issue only impacts SoftIron HyperCloud and related software products (such as VM Squared) software versions 2.3.0 to before 2.5.0. |
| When installing Nessus Agent to a directory outside of the default location on a Windows host, Nessus Agent versions prior to 10.6.4 did not enforce secure permissions for sub-directories. This could allow for local privilege escalation if users had not secured the directories in the non-default installation location. |
| The WooCommerce Cloak Affiliate Links plugin for WordPress is vulnerable to unauthorized modification of data due to a missing capability check on the 'permalink_settings_save' function in all versions up to, and including, 1.0.33. This makes it possible for unauthenticated attackers to modify the affiliate permalink base, driving traffic to malicious sites via the plugin's affiliate links. |
| The PayU CommercePro Plugin plugin for WordPress is vulnerable to privilege escalation in all versions up to, and including, 3.8.3. This is due to /wp-json/payu/v1/generate-user-token and /wp-json/payu/v1/get-shipping-cost REST API endpoints not properly verifying a user's identity prior to setting the users ID and auth cookies. This makes it possible for unauthenticated attackers to create new administrative user accounts. |
| IPP software prior to v1.71 is vulnerable to default credential vulnerability. This could
lead attackers to identify and access vulnerable systems. |
| The WordPress Tour & Travel Booking Plugin for WooCommerce – WpTravelly plugin for WordPress is vulnerable to unauthorized modification of data due to a missing capability check on the 'ttbm_new_place_save' function in all versions up to, and including, 1.7.1. This makes it possible for unauthenticated attackers to create and publish new place posts. This function is also vulnerable to CSRF. |
| Voltronic Power ViewPower through 1.04-21353 and PowerShield Netguard before 1.04-23292 allows a remote attacker to configure the system via an unspecified web interface. An unauthenticated remote attacker can make changes to the system including: changing the web interface admin password, view/change system configuration, enumerate connected UPS devices and shut down connected UPS devices. This extends to being able to configure operating system commands that should run if the system detects a connected UPS shutting down. |
| Certain models of routers from Billion Electric has an Authentication Bypass vulnerability, allowing unautheticated attackers to retrive contents of arbitrary web pages. |
| A vulnerability classified as critical was found in CP Plus Wi-Fi Camera up to 20240401. Affected by this vulnerability is an unknown functionality of the component User Management. The manipulation leads to improper authorization. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-259615. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. |
| The JobSearch WP Job Board plugin for WordPress is vulnerable to privilege escalation in all versions up to, and including, 2.6.7. This is due to the plugin not properly verifying a users identity when verifying an email address through the user_account_activation function. This makes it possible for unauthenticated attackers to log in as any user, including site administrators if the users email is known. |
| jeewx-boot 1.3 has an authentication bypass vulnerability in the preHandle function |
| Lexmark MX6500 LW75.JD.P296 and previous devices have Incorrect Access Control via the access control settings. |
| A vulnerability was discovered in the Alta Recovery Vault feature of Veritas NetBackup before 10.4 and NetBackup Appliance before 5.4. By design, only the cloud administrator should be able to disable the retention lock of Governance mode images. This vulnerability allowed a NetBackup administrator to modify the expiration of backups under Governance mode (which could cause premature deletion). |
| BPL Personal Weighing Scale PWS-01BT IND/09/18/599 devices send sensitive information in unencrypted BLE packets. (The packet data also lacks authentication and integrity protection.) |
| Weak access control in OpenText PVCS Version Manager allows potential bypassing of authentication and uploading of files. |