Search Results (427 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-61481 1 Mikrotik 2 Routeros, Switchos 2026-04-15 10 Critical
An issue in MikroTik RouterOS v.7.14.2 and SwOS v.2.18 exposes the WebFig management interface over cleartext HTTP by default, allowing an on-path attacker to execute injected JavaScript in the administrator’s browser and intercept credentials.
CVE-2025-54514 1 Amd 10 Epyc 9005 Series Processors, Epyc Embedded 9005 Series Processors, Ryzen 5000 Series Desktop Processors and 7 more 2026-04-15 N/A
Improper isolation of shared resources on a system on a chip by a malicious local attacker with high privileges could potentially lead to a partial loss of integrity.
CVE-2025-53602 2026-04-15 5.3 Medium
Zipkin through 3.5.1 has a /heapdump endpoint (associated with the use of Spring Boot Actuator), a similar issue to CVE-2025-48927.
CVE-2025-1863 2026-04-15 9.8 Critical
Insecure default settings have been found in recorder products provided by Yokogawa Electric Corporation. The default setting of the authentication function is disabled on the affected products. Therefore, when connected to a network with default settings, anyone can access all functions related to settings and operations. As a result, an attacker can illegally manipulate and configure important data such as measured values and settings. This issue affects GX10 / GX20 / GP10 / GP20 Paperless Recorders: R5.04.01 or earlier; GM Data Acquisition System: R5.05.01 or earlier; DX1000 / DX2000 / DX1000N Paperless Recorders: R4.21 or earlier; FX1000 Paperless Recorders: R1.31 or earlier; μR10000 / μR20000 Chart Recorders: R1.51 or earlier; MW100 Data Acquisition Units: All versions; DX1000T / DX2000T Paperless Recorders: All versions; CX1000 / CX2000 Paperless Recorders: All versions.
CVE-2024-5801 2026-04-15 N/A
Enabled IP Forwarding feature in B&R Automation Runtime versions before 6.0.2 may allow remote attack-ers to compromise network security by routing IP-based packets through the host, potentially by-passing firewall, router, or NAC filtering.
CVE-2024-28815 1 Mitel 2 Cmg Suite, Inattend 2026-04-15 9.8 Critical
A vulnerability in the BluStar component of Mitel InAttend 2.6 SP4 through 2.7 and CMG 8.5 SP4 through 8.6 could allow access to sensitive information, changes to the system configuration, or execution of arbitrary commands within the context of the system.
CVE-2024-2912 1 Bentoml 1 Bentoml 2026-04-15 10 Critical
An insecure deserialization vulnerability exists in the BentoML framework, allowing remote code execution (RCE) by sending a specially crafted POST request. By exploiting this vulnerability, attackers can execute arbitrary commands on the server hosting the BentoML application. The vulnerability is triggered when a serialized object, crafted to execute OS commands upon deserialization, is sent to any valid BentoML endpoint. This issue poses a significant security risk, enabling attackers to compromise the server and potentially gain unauthorized access or control.
CVE-2025-31930 2026-04-15 8.8 High
A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions < V2.135), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions < V2.135), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions < V2.135), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions < V2.135), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions < V2.135), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions < V2.135), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions < V2.135). Affected devices contain Modbus service enabled by default. This could allow an attacker connected to the same network to remotely control the EV charger.
CVE-2024-51758 1 Filament 1 Excel Export 2026-04-15 N/A
Filament is a collection of full-stack components for accelerated Laravel development. All Filament features that interact with storage use the `default_filesystem_disk` config option. This allows the user to easily swap their storage driver to something production-ready like `s3` when deploying their app, without having to touch multiple configuration options and potentially forgetting about some. The default disk is set to `public` when you first install Filament, since this allows users to quickly get started developing with a functional disk that allows features such as file upload previews locally without the need to set up an S3 disk with temporary URL support. However, some features of Filament such as exports also rely on storage, and the files that are stored contain data that should often not be public. This is not an issue for the many deployed applications, since many use a secure default disk such as S3 in production. However, [CWE-1188](https://cwe.mitre.org/data/definitions/1188.html) suggests that having the `public` disk as the default disk in Filament is a security vulnerability itself. As such, we have implemented a measure to protect users whereby if the `public` disk is set as the default disk, the exports feature will automatically swap it out for the `local` disk, if that exists. Users who set the default disk to `local` or `s3` already are not affected. If a user wants to continue to use the `public` disk for exports, they can by setting the export disk deliberately. This change has been included in the 3.2.123 release and all users who use the `public` disk are advised to upgrade.
CVE-2025-2442 2026-04-15 6.8 Medium
CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could potentially lead to unauthorized access which could result in the loss of confidentially, integrity and availability when a malicious user, having physical access, sets the radio to the factory default mode.
CVE-2025-2441 2026-04-15 4.6 Medium
CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could lead to loss of confidentiality when a malicious user, having physical access, sets the radio in factory default mode where the product does not correctly initialize all data.
CVE-2025-41438 2026-04-15 9.8 Critical
The CS5000 Fire Panel is vulnerable due to a default account that exists on the panel. Even though it is possible to change this by SSHing into the device, it has remained unchanged on every installed system observed. This account is not root but holds high-level permissions that could severely impact the device's operation if exploited.
CVE-2025-62877 1 Suse 1 Harvester 2026-04-15 9.8 Critical
Projects using the SUSE Virtualization (Harvester) environment may expose the OS default ssh login password  if they are using the 1.5.x or 1.6.x interactive installer to either create a new cluster or add new hosts to an existing cluster. The environment is not affected if the PXE boot mechanism is utilized along with the Harvester configuration setup.
CVE-2025-52622 1 Hcltech 1 Bigfix Saas 2026-04-15 5.4 Medium
The BigFix SaaS's HTTP responses were missing some security headers. The absence of these headers weakens the application's client-side security posture, making it more vulnerable to common web attacks that these headers are designed to mitigate, such as Cross-Site Scripting (XSS), Clickjacking, and protocol downgrade attacks.
CVE-2025-41713 1 Wago 1 Cc100 2026-04-15 6.5 Medium
During a short time frame while the device is booting an unauthenticated remote attacker can send traffic to unauthorized networks due to the switch operating in an undefined state until a CPU-induced reset allows proper configuration.
CVE-2025-41672 1 Wago 1 Device Sphere 2026-04-15 10 Critical
A remote unauthenticated attacker may use default certificates to generate JWT Tokens and gain full access to the tool and all connected devices.
CVE-2025-41245 1 Vmware 3 Aria Operations, Cloud Foundation, Tools 2026-04-15 4.9 Medium
VMware Aria Operations contains an information disclosure vulnerability. A malicious actor with non-administrative privileges in Aria Operations may exploit this vulnerability to disclose credentials of other users of Aria Operations.
CVE-2025-2129 2026-04-15 5.6 Medium
A vulnerability was found in Mage AI 0.9.75. It has been classified as problematic. This affects an unknown part. The manipulation leads to insecure default initialization of resource. It is possible to initiate the attack remotely. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. After 7 months of repeated follow-ups by the researcher, Mage AI has decided to not accept this issue as a valid security vulnerability and has confirmed that they will not be addressing it.
CVE-2025-1960 2026-04-15 9.8 Critical
CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could cause an attacker to execute unauthorized commands when a system’s default password credentials have not been changed on first use. The default username is not displayed correctly in the WebHMI interface.
CVE-2024-25972 1 Atsumi 1 Oet-213h-bts1 2026-04-15 8.3 High
Initialization of a resource with an insecure default vulnerability in OET-213H-BTS1 sold in Japan by Atsumi Electric Co., Ltd. allows a network-adjacent unauthenticated attacker to configure and control the affected product.