| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| InfluxDB OSS 2.x through 2.7.11 stores the administrative operator token under the default organization which allows authorized users with read access to the authorization resource of the default organization to retrieve the operator token. InfluxDB OSS 1.x, Enterprise, Cloud, Cloud Dedicated and Clustered are not affected. NOTE: The researcher states that InfluxDB allows allAccess administrators to retrieve all raw tokens via an "influx auth ls" command. The supplier indicates that the organizations feature is operating as intended and that users may choose to add users to non-default organizations. A future release of InfluxDB 2.x will remove the ability to retrieve tokens from the API. The supplier has stated that InfluxDB 2.8.0 has addressed this issue. |
|
An implicit intent vulnerability was reported for Motorola’s Time Weather Widget application that could allow a local application to acquire the location of the device without authorization.
|
| Improper buffer restrictions in some Intel(R) Graphics Drivers may allow an authenticated user to potentially enable denial of service via local access. |
| Mullvad VPN through 2024.1 on Android does not set a DNS server in the blocking state (after a hard failure to create a tunnel), and thus DNS traffic can leave the device. Data showing that the affected device was the origin of sensitive DNS requests may be observed and logged by operators of unintended DNS servers. |
| The Advanced Contact form 7 DB plugin for WordPress is vulnerable to Sensitive Information Exposure in all versions up to, and including, 2.0.2 via the wp-content/uploads/advanced-cf7-upload directory. This makes it possible for unauthenticated attackers to extract sensitive data uploaded via this plugin through a form. |
| NVIDIA RunAI for all platforms contains a vulnerability where a user could cause an improper restriction of communications channels on an adjacent network. A successful exploit of this vulnerability might lead to escalation of privileges, data tampering, and information disclosure. |
| A Gardyn Azure IoT Hub connection string is downloaded over an insecure HTTP connection in Gardyn Home Kit firmware before master.619, Home Kit Mobile Application before 2.11.0, and Home Kit Cloud API before 2.12.2026 leaving the string vulnerable to interception and modification through a Man-in-the-Middle attack. This may result in the attacker capturing device credentials or taking control of vulnerable home kits. |
| CWE-922: Insecure Storage of Sensitive Information vulnerability exists that could potentially lead to unauthorized
access of confidential data when a malicious user, having physical access and advanced information on the file
system, sets the radio in factory default mode. |
| Information Disclosure in API in Replicated Replicated Classic versions prior to 2.53.1 on all platforms allows authenticated users with Admin Console access to retrieve sensitive data, including application secrets, via accessing container definitions with environment variables through the Admin Console API on port 8800.
This CVE was originally reserved in 2021 and later publicly disclosed by Replicated on their website on 21 October 2021. However, it mistakenly remained in the Reserved But Public (RBP) status with the CVE Numbering Authority (CNA). Please note that this product reached its end of life on 31 December 2024. Publishing this CVE with the CNA was required to comply with CNA rules, despite the fact that the issue was disclosed and fixed four years ago, and the affected product is no longer supported as of 2024.
Summary of VulnerabilityThis advisory discloses a low severity security vulnerability in the versions of Replicated Classic listed above (“Affected Replicated Classic Versions”)
DescriptionReplicated Classic versions prior to 2.53.1 have an authenticated API from the Replicated Admin Console that may expose sensitive data including application secrets, depending on how the application manifests are written. A user with valid credentials and access to the Admin Console port (8800) on the Replicated Classic server can retrieve container definitions including environment variables which may contain passwords and other secrets depending on how the application is configured.
This data is shared over authenticated sessions to the Admin Console only, and was never displayed or used in the application processing. To remediate this issue, we removed the sensitive data from the API, sending only the data to the Admin Console that was needed.
TimelineThis issue was discovered during a security review on 16 September 2021.
Patched versions were released on 23 September 2021.
This advisory was published on 21 October 2021.
The CVE Numbering Authority (CNA) notified Replicated on 23 January 2025 that the CVE was still in Reserved But Public (RBP) status. Upon discovering the oversight in updating the status to published with the CNA, Replicated submitted the updated report on the same day, 23 January 2025. |
| A security issue was discovered within the legacy ADI server component of Verve Asset Manager, caused by plaintext secrets stored in environment variables on the ADI server. This component has been retired and has been optional since the 1.36 release in 2024. |
| A vulnerability has been found in Seismic App 2.4.2 on Android. Affected is an unknown function of the file AndroidManifest.xml of the component com.seismic.doccenter. Such manipulation leads to improper export of android application components. An attack has to be approached locally. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| udn News Android APP stores the unencrypted user session in the local database when user log into the application. A malicious APP or an attacker with physical access to the Android device can retrieve this session and use it to log into the news APP and other services provided by udn. |
| Cross Application Scripting vulnerability in Vercom S.A. Redlink SDK in specific situations allows local code injection and to manipulate the view of a vulnerable application.This issue affects Redlink SDK versions through 1.13. |
| An issue in Midea Group Co., Ltd Midea Home iOS 9.3.12 allows attackers to access sensitive user information via supplying a crafted link. |
| An issue in Zhiyuan Yuedu (Guangzhou) Literature Information Technology Co., Ltd Shuqi Novel iOS 5.3.8 allows attackers to access sensitive user information via supplying a crafted link. |
| An issue in Shenzhen Intellirocks Tech Co. Ltd Govee Home iOS 6.5.01 allows attackers to access sensitive user information via supplying a crafted payload. |
| An issue in Cloud Whale Interactive Technology LLC. PolyBuzz iOS 2.0.20 allows attackers to access sensitive user information via supplying a crafted link. |
| An issue in Shanghai Xuan Ting Entertainment Information & Technology Co., Ltd Qidian Reader iOS 5.9.384 allows attackers to access sensitive user information via supplying a crafted link. |
| Improper conditions check in some Intel(R) BIOS Guard firmware may allow a privileged user to potentially enable escalation of privilege via local access. |
| An issue in Shanghai Shizhi Information Technology Co., Ltd Shihuo iOS 8.16.0 allows attackers to access sensitive user information via supplying a crafted link. |